Chemical Oxygen Demand
08a91e70-3ddc-11dd-97ee-0050c2490048
Identity
- Substance
- fo-44ac622598b3431b Aggregate measurement
- Source
- EF 3.1
- Unit
- kg
- Context
- Environmental → Water → Long-term
- CAS
- —
- EC
- —
Context
- Dimension
- Environmental
- Media
- Water
- Water body
- Long-term
Source lists
5| List | Version | Source flow | Name there | Why this flow |
|---|---|---|---|---|
| EF | 3.1 | 08a91e70-3ddc-11dd-97ee-0050c2490048 | chemical oxygen demand | The consensus list is built from this one, so this row is the flow itself rather than something matched to it. |
| agribalyse | 3.2 | 0fa1a758-ee59-5978-bdfd-302fde465617 | COD (Chemical Oxygen Demand) | This substance answers to the name the row carries; both name the same compartment. |
| bafu | 2026-v1 | 0af35a72-ee8e-5c72-8839-6a6f9acb2933 | COD, Chemical Oxygen Demand | This substance answers to the name the row carries; both name the same compartment. |
| ecoinvent | 3.12 | a8fea8cf-9b09-49fc-aa58-5a732494a2a0 | COD, Chemical Oxygen Demand | This substance answers to the name the row carries; both name the same compartment. |
| ecoinvent | 3.8 | a8fea8cf-9b09-49fc-aa58-5a732494a2a0 | COD, Chemical Oxygen Demand | This substance answers to the name the row carries; both name the same compartment. |
Concept associations
5| Source list | Source flow | Name there | Compartment there | Match | Conversion |
|---|---|---|---|---|---|
| EF 3.1 | 08a91e70-3ddc-11dd-97ee-0050c2490048 | chemical oxygen demand | Emissions/Emissions to water/Emissions to water, unspecified (long-term) | exactMatch | — |
| ecoinvent 3.12 | a8fea8cf-9b09-49fc-aa58-5a732494a2a0 | COD, Chemical Oxygen Demand | water / ground-, long-term | closeMatch | — |
| ecoinvent 3.8 | a8fea8cf-9b09-49fc-aa58-5a732494a2a0 | COD, Chemical Oxygen Demand | water / ground-, long-term | closeMatch | — |
| bafu 2026-v1 | 0af35a72-ee8e-5c72-8839-6a6f9acb2933 | COD, Chemical Oxygen Demand | emissions to water / groundwater, long-term | closeMatch | — |
| agribalyse 3.2 | 0fa1a758-ee59-5978-bdfd-302fde465617 | COD (Chemical Oxygen Demand) | Emissions to water / groundwater, long-term | closeMatch | — |
History
The change log and the PROV-O trail (0 consensus changes)
These are the heaviest sections of this page and the least often read, so the page does not pay for them until you ask.
Full record
Flow JSON
{
"altLabel": [],
"properties": {
"https://vocab.brightway.one/terms/expressedAs": {
"rdfs:label": "expressed as",
"@value": [
{
"@id": "https://vocab.brightway.dev/flow-objects/fo-fb432c4d5067c1b9"
}
],
"provenance": {
"prov:wasGeneratedBy": "semantic_typing.classify",
"prov:wasAttributedTo": "brightway-flows",
"prov:wasDerivedFrom": "aggregate_measurements.expressed_as"
}
}
},
"references": [],
"prefLabel": [
{
"@value": "Chemical Oxygen Demand",
"@language": "en",
"source": {
"prov:wasGeneratedBy": "bootstrap_labels",
"prov:wasAttributedTo": "brightway-flows",
"prov:hadPrimarySource": [
"EF 3.1"
],
"prov:wasDerivedFrom": "legacy name field"
}
}
],
"@type": [
"https://vocab.brightway.one/terms/AggregateMeasurement"
],
"uuid": "08a91e70-3ddc-11dd-97ee-0050c2490048",
"identifier": "08a91e70-3ddc-11dd-97ee-0050c2490048",
"source": "EF 3.1",
"cas_numbers": [],
"ec_numbers": [],
"context": {
"dimension": "Environmental",
"media": "Water",
"water_body": "Long-term"
},
"synonyms": [],
"lcia_methods": [],
"unit": "kg",
"input_datasets": [
"EF 3.1"
],
"context_iri": "https://vocab.brightway.one/flow-contexts/envi-wate-lote",
"unit_iri": "https://vocab.brightway.one/units/unit/KiloGM",
"flow_object_id": "fo-44ac622598b3431b",
"concept_associations": [
{
"@type": "xkos:ConceptAssociation",
"xkos:sourceConcept": {
"@id": "https://vocab.brightway.one/ef/3.1/flow/08a91e70-3ddc-11dd-97ee-0050c2490048",
"skos:prefLabel": "chemical oxygen demand",
"context": "Emissions/Emissions to water/Emissions to water, unspecified (long-term)",
"qudt:hasUnit": {
"@id": "https://vocab.brightway.one/units/unit/KiloGM"
},
"skos:exactMatch": {
"@id": "https://vocab.brightway.dev/elementary-flows/08a91e70-3ddc-11dd-97ee-0050c2490048"
}
},
"xkos:targetConcept": {
"@id": "https://vocab.brightway.dev/elementary-flows/08a91e70-3ddc-11dd-97ee-0050c2490048"
},
"provenance": {
"prov:wasGeneratedBy": "build_concept_associations",
"prov:wasAttributedTo": "brightway-flows",
"prov:hadPrimarySource": [
"https://eplca.jrc.ec.europa.eu/permalink/EF3_1/EF-v3.1.zip"
]
}
},
{
"@type": "xkos:ConceptAssociation",
"xkos:sourceConcept": {
"@id": "https://vocab.brightway.one/ecoinvent/3.12/flow/a8fea8cf-9b09-49fc-aa58-5a732494a2a0",
"skos:prefLabel": "COD, Chemical Oxygen Demand",
"context": "water / ground-, long-term",
"qudt:hasUnit": {
"@id": "https://vocab.brightway.one/units/unit/KiloGM"
},
"skos:closeMatch": {
"@id": "https://vocab.brightway.dev/elementary-flows/08a91e70-3ddc-11dd-97ee-0050c2490048"
}
},
"xkos:targetConcept": {
"@id": "https://vocab.brightway.dev/elementary-flows/08a91e70-3ddc-11dd-97ee-0050c2490048"
},
"provenance": {
"prov:wasGeneratedBy": "merge_ecoinvent",
"prov:wasAttributedTo": "brightway-flows",
"prov:hadPrimarySource": [
"ecoinvent:3.12:a8fea8cf-9b09-49fc-aa58-5a732494a2a0",
"COD, Chemical Oxygen Demand",
"",
"algorithm.lookup_order=cas>ec>label",
"algorithm.basis=label:chemical oxygen demand; cod",
"algorithm.flow_object_candidates=1",
"algorithm.elementary_candidates=4",
"algorithm.selector_reason=exact-context-iri-match",
"algorithm.score_rule=exact-iri-shortcircuit;up-tree-filter;score=(2*unit_exact)+context_overlap-context_penalty+context_iri_exact;contradiction-veto"
],
"prov:wasDerivedFrom": "algorithmic_fallback:lookup_order(cas>ec>label);basis(label:chemical oxygen demand; cod);flow_object_candidates(1);elementary_candidates(4);selector(exact-context-iri-match);exact-iri-shortcircuit;up-tree-filter;score=(2*unit_exact)+context_overlap-context_penalty+context_iri_exact;contradiction-veto"
}
},
{
"@type": "xkos:ConceptAssociation",
"xkos:sourceConcept": {
"@id": "https://vocab.brightway.one/ecoinvent/3.8/flow/a8fea8cf-9b09-49fc-aa58-5a732494a2a0",
"skos:prefLabel": "COD, Chemical Oxygen Demand",
"context": "water / ground-, long-term",
"qudt:hasUnit": {
"@id": "https://vocab.brightway.one/units/unit/KiloGM"
},
"skos:closeMatch": {
"@id": "https://vocab.brightway.dev/elementary-flows/08a91e70-3ddc-11dd-97ee-0050c2490048"
}
},
"xkos:targetConcept": {
"@id": "https://vocab.brightway.dev/elementary-flows/08a91e70-3ddc-11dd-97ee-0050c2490048"
},
"provenance": {
"prov:wasGeneratedBy": "merge_ecoinvent",
"prov:wasAttributedTo": "brightway-flows",
"prov:hadPrimarySource": [
"ecoinvent:3.8:a8fea8cf-9b09-49fc-aa58-5a732494a2a0",
"COD, Chemical Oxygen Demand",
"",
"algorithm.lookup_order=cas>ec>label",
"algorithm.basis=label:COD, Chemical Oxygen Demand",
"algorithm.flow_object_candidates=1",
"algorithm.elementary_candidates=5",
"algorithm.selector_reason=exact-context-iri-match",
"algorithm.score_rule=exact-iri-shortcircuit;up-tree-filter;score=(2*unit_exact)+context_overlap-context_penalty+context_iri_exact;contradiction-veto"
],
"prov:wasDerivedFrom": "algorithmic_fallback:lookup_order(cas>ec>label);basis(label:COD, Chemical Oxygen Demand);flow_object_candidates(1);elementary_candidates(5);selector(exact-context-iri-match);exact-iri-shortcircuit;up-tree-filter;score=(2*unit_exact)+context_overlap-context_penalty+context_iri_exact;contradiction-veto"
}
},
{
"@type": "xkos:ConceptAssociation",
"xkos:sourceConcept": {
"@id": "https://vocab.brightway.one/bafu/2026-v1/flow/0af35a72-ee8e-5c72-8839-6a6f9acb2933",
"skos:prefLabel": "COD, Chemical Oxygen Demand",
"context": "emissions to water / groundwater, long-term",
"qudt:hasUnit": {
"@id": "https://vocab.brightway.one/units/unit/KiloGM"
},
"skos:closeMatch": {
"@id": "https://vocab.brightway.dev/elementary-flows/08a91e70-3ddc-11dd-97ee-0050c2490048"
}
},
"xkos:targetConcept": {
"@id": "https://vocab.brightway.dev/elementary-flows/08a91e70-3ddc-11dd-97ee-0050c2490048"
},
"provenance": {
"prov:wasGeneratedBy": "merge_bafu",
"prov:wasAttributedTo": "brightway-flows",
"prov:hadPrimarySource": [
"bafu:2026-v1:0af35a72-ee8e-5c72-8839-6a6f9acb2933",
"COD, Chemical Oxygen Demand",
"",
"algorithm.lookup_order=cas>ec>label",
"algorithm.basis=label:COD, Chemical Oxygen Demand; Chemical Oxygen Demand",
"algorithm.flow_object_candidates=1",
"algorithm.elementary_candidates=5",
"algorithm.selector_reason=exact-context-iri-match",
"algorithm.score_rule=exact-iri-shortcircuit;up-tree-filter;score=(2*unit_exact)+context_overlap-context_penalty+context_iri_exact;contradiction-veto"
],
"prov:wasDerivedFrom": "algorithmic_fallback:lookup_order(cas>ec>label);basis(label:COD, Chemical Oxygen Demand; Chemical Oxygen Demand);flow_object_candidates(1);elementary_candidates(5);selector(exact-context-iri-match);exact-iri-shortcircuit;up-tree-filter;score=(2*unit_exact)+context_overlap-context_penalty+context_iri_exact;contradiction-veto"
}
},
{
"@type": "xkos:ConceptAssociation",
"xkos:sourceConcept": {
"@id": "https://vocab.brightway.one/agribalyse/3.2/flow/0fa1a758-ee59-5978-bdfd-302fde465617",
"skos:prefLabel": "COD (Chemical Oxygen Demand)",
"context": "Emissions to water / groundwater, long-term",
"qudt:hasUnit": {
"@id": "https://vocab.brightway.one/units/unit/KiloGM"
},
"skos:closeMatch": {
"@id": "https://vocab.brightway.dev/elementary-flows/08a91e70-3ddc-11dd-97ee-0050c2490048"
}
},
"xkos:targetConcept": {
"@id": "https://vocab.brightway.dev/elementary-flows/08a91e70-3ddc-11dd-97ee-0050c2490048"
},
"provenance": {
"prov:wasGeneratedBy": "merge_agribalyse",
"prov:wasAttributedTo": "brightway-flows",
"prov:hadPrimarySource": [
"agribalyse:3.2:0fa1a758-ee59-5978-bdfd-302fde465617",
"COD (Chemical Oxygen Demand)",
"",
"algorithm.lookup_order=cas>ec>label",
"algorithm.basis=label:Chemical Oxygen Demand",
"algorithm.flow_object_candidates=1",
"algorithm.elementary_candidates=6",
"algorithm.selector_reason=exact-context-iri-match",
"algorithm.score_rule=exact-iri-shortcircuit;up-tree-filter;score=(2*unit_exact)+context_overlap-context_penalty+context_iri_exact;contradiction-veto"
],
"prov:wasDerivedFrom": "algorithmic_fallback:lookup_order(cas>ec>label);basis(label:Chemical Oxygen Demand);flow_object_candidates(1);elementary_candidates(6);selector(exact-context-iri-match);exact-iri-shortcircuit;up-tree-filter;score=(2*unit_exact)+context_overlap-context_penalty+context_iri_exact;contradiction-veto"
}
}
],
"_sources": {
"prefLabel": "normalize_name_case",
"name": "bootstrap_labels",
"context": "default_context_mapping",
"context_iri": "default_context_mapping",
"unit_iri": "unit_normalization",
"concept_associations": "carry_associations_onto_flows",
"types": "link_flows_to_their_substance",
"properties": "link_flows_to_their_substance"
},
"general_comment": "The individual substances are to be inventoried, wherever possible. Highly impacting substances may not be \"hidden\" via using this sum-indicator. Reference elementary flow of the International Reference Life Cycle Data System (ILCD).",
"_transformed": true,
"_provided": {
"name": "chemical oxygen demand",
"synonyms": [],
"context": [
"Emissions",
"Emissions to water",
"Emissions to water, unspecified (long-term)"
],
"cas_numbers": [],
"ec_numbers": [],
"unit": "kg"
}
}
Something wrong here?
A flow can be wrong in three ways, and they are decided differently. Pick the one that matches what you are looking at.
- A row from my list should not reach this flow
- This flow is not that chemical
- The compartment or the unit is wrong
You do not need to run a build or clone anything. Name the row and say what your evidence is; the measurement is done for you. How contributing works