Brightway Flows 1.0
GitHub

Identity

Substance
fo-7746cc86aa4c474a Imprecise chemical mixture
Source
EF 3.1
Unit
kg
Context
Environmental → Air → Ground level → Urban (>1000 people/square mile)
CAS
8016-81-7
EC
232-414-4

Context

Dimension
Environmental
Media
Air
Population density
Urban (>1000 people/square mile)
Strata
Ground level

Alternative labels

12

Source lists

1
List Version Source flow Name there Why this flow
EF 3.1 49671278-f80a-4e0a-9b24-602b1d7de2f6 tall-oil pitch The consensus list is built from this one, so this row is the flow itself rather than something matched to it.

Concept associations

1
Source list Source flow Name there Compartment there Match Conversion
EF 3.1 49671278-f80a-4e0a-9b24-602b1d7de2f6 tall-oil pitch Emissions/Emissions to air/Emissions to urban air close to ground exactMatch —

Characterisation factors

4

Every implementation that says anything about this flow. Published as is what this list did with the row: where more than one implementation states a number and they agree it publishes it as agreed; where only one speaks, as sole; where they disagree it publishes nothing and asks.

Method Implementation Category Place Factor Published as
EF 3.1 European Commission — JRC Ecotoxicity, freshwater — 0.26455 —
EF 3.1 brightway-flows Ecotoxicity, freshwater — 0.26455 sole
EF 3.1 European Commission — JRC Ecotoxicity, freshwater_organics — 0.26455 —
EF 3.1 brightway-flows Ecotoxicity, freshwater_organics — 0.26455 sole

This flow in the difference report

History

The change log and the PROV-O trail (2 consensus changes)

Open the changes page

These are the heaviest sections of this page and the least often read, so the page does not pay for them until you ask.

Full record

Flow JSON
{
  "altLabel": [
    {
      "@value": "Hartall TP",
      "@language": "en",
      "source": {
        "prov:wasGeneratedBy": "consensus_match",
        "prov:wasAttributedTo": "brightway-flows",
        "prov:hadPrimarySource": [
          "CAS:8016-81-7",
          "https://commonchemistry.cas.org/detail?cas_rn=8016-81-7"
        ],
        "prov:wasDerivedFrom": "common chemistry CAS lookup"
      }
    },
    {
      "@value": "KTP",
      "@language": "en",
      "source": {
        "prov:wasGeneratedBy": "consensus_match",
        "prov:wasAttributedTo": "brightway-flows",
        "prov:hadPrimarySource": [
          "CAS:8016-81-7",
          "https://commonchemistry.cas.org/detail?cas_rn=8016-81-7"
        ],
        "prov:wasDerivedFrom": "common chemistry CAS lookup"
      }
    },
    {
      "@value": "KTP (pitch)",
      "@language": "en",
      "source": {
        "prov:wasGeneratedBy": "consensus_match",
        "prov:wasAttributedTo": "brightway-flows",
        "prov:hadPrimarySource": [
          "CAS:8016-81-7",
          "https://commonchemistry.cas.org/detail?cas_rn=8016-81-7"
        ],
        "prov:wasDerivedFrom": "common chemistry CAS lookup"
      }
    },
    {
      "@value": "PK-L",
      "@language": "en",
      "source": {
        "prov:wasGeneratedBy": "consensus_match",
        "prov:wasAttributedTo": "brightway-flows",
        "prov:hadPrimarySource": [
          "CAS:8016-81-7",
          "https://commonchemistry.cas.org/detail?cas_rn=8016-81-7"
        ],
        "prov:wasDerivedFrom": "common chemistry CAS lookup"
      }
    },
    {
      "@value": "Pektanoks",
      "@language": "en",
      "source": {
        "prov:wasGeneratedBy": "consensus_match",
        "prov:wasAttributedTo": "brightway-flows",
        "prov:hadPrimarySource": [
          "CAS:8016-81-7",
          "https://commonchemistry.cas.org/detail?cas_rn=8016-81-7"
        ],
        "prov:wasDerivedFrom": "common chemistry CAS lookup"
      }
    },
    {
      "@value": "Pitch, tall-oil",
      "@language": "en",
      "source": {
        "prov:wasGeneratedBy": "consensus_match",
        "prov:wasAttributedTo": "brightway-flows",
        "prov:hadPrimarySource": [
          "CAS:8016-81-7",
          "https://commonchemistry.cas.org/detail?cas_rn=8016-81-7"
        ],
        "prov:wasDerivedFrom": "common chemistry CAS lookup"
      }
    },
    {
      "@value": "Road Oyl",
      "@language": "en",
      "source": {
        "prov:wasGeneratedBy": "consensus_match",
        "prov:wasAttributedTo": "brightway-flows",
        "prov:hadPrimarySource": [
          "CAS:8016-81-7",
          "https://commonchemistry.cas.org/detail?cas_rn=8016-81-7"
        ],
        "prov:wasDerivedFrom": "common chemistry CAS lookup"
      }
    },
    {
      "@value": "Sylfat DP 1",
      "@language": "en",
      "source": {
        "prov:wasGeneratedBy": "consensus_match",
        "prov:wasAttributedTo": "brightway-flows",
        "prov:hadPrimarySource": [
          "CAS:8016-81-7",
          "https://commonchemistry.cas.org/detail?cas_rn=8016-81-7"
        ],
        "prov:wasDerivedFrom": "common chemistry CAS lookup"
      }
    },
    {
      "@value": "Tall oil pitch",
      "@language": "en",
      "source": {
        "prov:wasGeneratedBy": "consensus_match",
        "prov:wasAttributedTo": "brightway-flows",
        "prov:hadPrimarySource": [
          "CAS:8016-81-7",
          "https://commonchemistry.cas.org/detail?cas_rn=8016-81-7"
        ],
        "prov:wasDerivedFrom": "common chemistry CAS lookup"
      }
    },
    {
      "@value": "Terpak P 40",
      "@language": "en",
      "source": {
        "prov:wasGeneratedBy": "consensus_match",
        "prov:wasAttributedTo": "brightway-flows",
        "prov:hadPrimarySource": [
          "CAS:8016-81-7",
          "https://commonchemistry.cas.org/detail?cas_rn=8016-81-7"
        ],
        "prov:wasDerivedFrom": "common chemistry CAS lookup"
      }
    },
    {
      "@value": "Unitol DCP 6",
      "@language": "en",
      "source": {
        "prov:wasGeneratedBy": "consensus_match",
        "prov:wasAttributedTo": "brightway-flows",
        "prov:hadPrimarySource": [
          "CAS:8016-81-7",
          "https://commonchemistry.cas.org/detail?cas_rn=8016-81-7"
        ],
        "prov:wasDerivedFrom": "common chemistry CAS lookup"
      }
    },
    {
      "@value": "Unitol DP 6",
      "@language": "en",
      "source": {
        "prov:wasGeneratedBy": "consensus_match",
        "prov:wasAttributedTo": "brightway-flows",
        "prov:hadPrimarySource": [
          "CAS:8016-81-7",
          "https://commonchemistry.cas.org/detail?cas_rn=8016-81-7"
        ],
        "prov:wasDerivedFrom": "common chemistry CAS lookup"
      }
    }
  ],
  "properties": {},
  "references": [
    {
      "@id": "https://commonchemistry.cas.org/detail?cas_rn=8016-81-7",
      "provenance": {
        "prov:wasGeneratedBy": "enrich_references.consensus_cas_link",
        "prov:wasAttributedTo": "brightway-flows",
        "prov:hadPrimarySource": [
          "8016-81-7"
        ],
        "prov:wasDerivedFrom": "cas_numbers"
      }
    }
  ],
  "prefLabel": [
    {
      "@value": "Tall-oil Pitch",
      "@language": "en",
      "source": {
        "prov:wasGeneratedBy": "bootstrap_labels",
        "prov:wasAttributedTo": "brightway-flows",
        "prov:hadPrimarySource": [
          "EF 3.1"
        ],
        "prov:wasDerivedFrom": "legacy name field"
      }
    }
  ],
  "@type": [
    "https://w3id.org/chemrof/ImpreciseChemicalMixture"
  ],
  "http://www.w3.org/2004/02/skos/core#definition": [],
  "uuid": "49671278-f80a-4e0a-9b24-602b1d7de2f6",
  "identifier": "49671278-f80a-4e0a-9b24-602b1d7de2f6",
  "source": "EF 3.1",
  "cas_numbers": [
    "8016-81-7"
  ],
  "ec_numbers": [
    "232-414-4"
  ],
  "context": {
    "dimension": "Environmental",
    "media": "Air",
    "strata": "Ground level",
    "population_density": "Urban (>1000 people/square mile)"
  },
  "synonyms": [],
  "lcia_methods": [
    {
      "method_uuid": "05316e7a-b254-4bea-9cf0-6bf33eb5c630",
      "name": "Ecotoxicity, freshwater",
      "methodology": "Environmental Footprint",
      "impact_category": "Aquatic eco-toxicity",
      "impact_indicator": "Comparative Toxic Unit for ecosystems (CTUe) ",
      "characterization_factor": 0.26455
    },
    {
      "method_uuid": "fd530f00-9325-424a-92ef-aaac67922fd9",
      "name": "Ecotoxicity, freshwater_organics",
      "methodology": "Environmental Footprint",
      "impact_category": "Aquatic eco-toxicity",
      "impact_indicator": "Comparative Toxic Unit for ecosystems (CTUe) ",
      "characterization_factor": 0.26455
    }
  ],
  "unit": "kg",
  "input_datasets": [
    "EF 3.1"
  ],
  "context_iri": "https://vocab.brightway.one/flow-contexts/envi-air-grle-ur10pesq",
  "unit_iri": "https://vocab.brightway.one/units/unit/KiloGM",
  "flow_object_id": "fo-7746cc86aa4c474a",
  "concept_associations": [
    {
      "@type": "xkos:ConceptAssociation",
      "xkos:sourceConcept": {
        "@id": "https://vocab.brightway.one/ef/3.1/flow/49671278-f80a-4e0a-9b24-602b1d7de2f6",
        "skos:prefLabel": "tall-oil pitch",
        "context": "Emissions/Emissions to air/Emissions to urban air close to ground",
        "qudt:hasUnit": {
          "@id": "https://vocab.brightway.one/units/unit/KiloGM"
        },
        "skos:exactMatch": {
          "@id": "https://vocab.brightway.dev/elementary-flows/49671278-f80a-4e0a-9b24-602b1d7de2f6"
        }
      },
      "xkos:targetConcept": {
        "@id": "https://vocab.brightway.dev/elementary-flows/49671278-f80a-4e0a-9b24-602b1d7de2f6"
      },
      "provenance": {
        "prov:wasGeneratedBy": "build_concept_associations",
        "prov:wasAttributedTo": "brightway-flows",
        "prov:hadPrimarySource": [
          "https://eplca.jrc.ec.europa.eu/permalink/EF3_1/EF-v3.1.zip"
        ]
      }
    }
  ],
  "_sources": {
    "prefLabel": "normalize_name_case",
    "name": "bootstrap_labels",
    "synonyms": "bootstrap_labels",
    "context": "default_context_mapping",
    "context_iri": "default_context_mapping",
    "unit_iri": "unit_normalization",
    "skos_definition": "enrich_references",
    "references": "enrich_references",
    "altLabel": "strip_catalogue_altlabels",
    "cas_match_labels": "consensus_match",
    "concept_associations": "carry_associations_onto_flows",
    "types": "link_flows_to_their_substance"
  },
  "cas_match_labels": {
    "8016-81-7": "exactMatch"
  },
  "_transformed": true,
  "_provided": {
    "name": "tall-oil pitch",
    "synonyms": [
      "tall-oilpitch",
      "tall-oilpitchtheresiduefromthedistillationoftalloil.itcontainsprimarilyhigh-boilingestersoffattyacidsandrosin.itmayalsocontainneutralmaterials,freefattyacidsandrosinacids.",
      "top",
      "talloilpitch",
      "talloilpitch(o.rregistration)",
      "talloilpitchpn",
      "tall-oil pitch"
    ],
    "context": [
      "Emissions",
      "Emissions to air",
      "Emissions to urban air close to ground"
    ],
    "cas_numbers": [
      "8016-81-7"
    ],
    "ec_numbers": [
      "232-414-4"
    ],
    "unit": "kg"
  }
}

Something wrong here?

A flow can be wrong in three ways, and they are decided differently. Pick the one that matches what you are looking at.

You do not need to run a build or clone anything. Name the row and say what your evidence is; the measurement is done for you. How contributing works

Keyboard

?
Show or hide this map
/
Focus search
Esc
Close