Residues (petroleum), Hydrodesulfurized Atmospheric Tower
4bca0eb2-d7af-4811-9c53-f305cc932395
Identity
- Substance
- fo-ebe2a2d7438a7a3b Imprecise chemical mixture
- Source
- EF 3.1
- Unit
- kg
- Context
- Environmental → Air → Ground level → Urban (>1000 people/square mile)
- CAS
- 64742-78-5
- EC
- 265-181-2
Context
- Dimension
- Environmental
- Media
- Air
- Population density
- Urban (>1000 people/square mile)
- Strata
- Ground level
Alternative labels
1- Hydrodesulfurized atmospheric tower residuum (petroleum)
Source lists
1| List | Version | Source flow | Name there | Why this flow |
|---|---|---|---|---|
| EF | 3.1 | 4bca0eb2-d7af-4811-9c53-f305cc932395 | residues (petroleum), hydrodesulfurized atmospheric tower | The consensus list is built from this one, so this row is the flow itself rather than something matched to it. |
Concept associations
1| Source list | Source flow | Name there | Compartment there | Match | Conversion |
|---|---|---|---|---|---|
| EF 3.1 | 4bca0eb2-d7af-4811-9c53-f305cc932395 | residues (petroleum), hydrodesulfurized atmospheric tower | Emissions/Emissions to air/Emissions to urban air close to ground | exactMatch | — |
Characterisation factors
4- consensus-flow-list 2
- European Commission — JRC 2
Every implementation that says anything about this flow. Published as is what this list did with the row: where more than one implementation states a number and they agree it publishes it as agreed; where only one speaks, as sole; where they disagree it publishes nothing and asks.
| Method | Implementation | Category | Place | Factor | Published as |
|---|---|---|---|---|---|
| EF 3.1 | European Commission — JRC | Ecotoxicity, freshwater | — | 300.09 | — |
| EF 3.1 | consensus-flow-list | Ecotoxicity, freshwater | — | 300.09 | sole |
| EF 3.1 | European Commission — JRC | Ecotoxicity, freshwater_organics | — | 300.09 | — |
| EF 3.1 | consensus-flow-list | Ecotoxicity, freshwater_organics | — | 300.09 | sole |
History
The change log and the PROV-O trail (2 consensus changes)
These are the heaviest sections of this page and the least often read, so the page does not pay for them until you ask.
Full record
Flow JSON
{
"altLabel": [
{
"@value": "Hydrodesulfurized atmospheric tower residuum (petroleum)",
"@language": "en",
"source": {
"prov:wasGeneratedBy": "consensus_match",
"prov:wasAttributedTo": "consensus-flow-list",
"prov:hadPrimarySource": [
"CAS:64742-78-5",
"https://commonchemistry.cas.org/detail?cas_rn=64742-78-5"
],
"prov:wasDerivedFrom": "common chemistry CAS lookup"
}
}
],
"properties": {},
"references": [
{
"@id": "https://commonchemistry.cas.org/detail?cas_rn=64742-78-5",
"provenance": {
"prov:wasGeneratedBy": "enrich_references.consensus_cas_link",
"prov:wasAttributedTo": "consensus-flow-list",
"prov:hadPrimarySource": [
"64742-78-5"
],
"prov:wasDerivedFrom": "cas_numbers"
}
}
],
"prefLabel": [
{
"@value": "Residues (petroleum), Hydrodesulfurized Atmospheric Tower",
"@language": "en",
"source": {
"prov:wasGeneratedBy": "bootstrap_labels",
"prov:wasAttributedTo": "consensus-flow-list",
"prov:hadPrimarySource": [
"EF 3.1"
],
"prov:wasDerivedFrom": "legacy name field"
}
}
],
"@type": [
"https://w3id.org/chemrof/ImpreciseChemicalMixture"
],
"http://www.w3.org/2004/02/skos/core#definition": [],
"uuid": "4bca0eb2-d7af-4811-9c53-f305cc932395",
"identifier": "4bca0eb2-d7af-4811-9c53-f305cc932395",
"source": "EF 3.1",
"cas_numbers": [
"64742-78-5"
],
"ec_numbers": [
"265-181-2"
],
"context": {
"dimension": "Environmental",
"media": "Air",
"strata": "Ground level",
"population_density": "Urban (>1000 people/square mile)"
},
"synonyms": [],
"lcia_methods": [
{
"method_uuid": "05316e7a-b254-4bea-9cf0-6bf33eb5c630",
"name": "Ecotoxicity, freshwater",
"methodology": "Environmental Footprint",
"impact_category": "Aquatic eco-toxicity",
"impact_indicator": "Comparative Toxic Unit for ecosystems (CTUe) ",
"characterization_factor": 300.09
},
{
"method_uuid": "fd530f00-9325-424a-92ef-aaac67922fd9",
"name": "Ecotoxicity, freshwater_organics",
"methodology": "Environmental Footprint",
"impact_category": "Aquatic eco-toxicity",
"impact_indicator": "Comparative Toxic Unit for ecosystems (CTUe) ",
"characterization_factor": 300.09
}
],
"unit": "kg",
"input_datasets": [
"EF 3.1"
],
"context_iri": "https://vocab.brightway.one/flow-contexts/envi-air-grle-ur10pesq",
"unit_iri": "https://vocab.brightway.one/units/unit/KiloGM",
"flow_object_id": "fo-ebe2a2d7438a7a3b",
"concept_associations": [
{
"@type": "xkos:ConceptAssociation",
"xkos:sourceConcept": {
"@id": "https://vocab.brightway.one/ef/3.1/flow/4bca0eb2-d7af-4811-9c53-f305cc932395",
"skos:prefLabel": "residues (petroleum), hydrodesulfurized atmospheric tower",
"context": "Emissions/Emissions to air/Emissions to urban air close to ground",
"qudt:hasUnit": {
"@id": "https://vocab.brightway.one/units/unit/KiloGM"
},
"skos:exactMatch": {
"@id": "https://vocab.brightway.dev/elementary-flows/4bca0eb2-d7af-4811-9c53-f305cc932395"
}
},
"xkos:targetConcept": {
"@id": "https://vocab.brightway.dev/elementary-flows/4bca0eb2-d7af-4811-9c53-f305cc932395"
},
"provenance": {
"prov:wasGeneratedBy": "build_concept_associations",
"prov:wasAttributedTo": "consensus-flow-list",
"prov:hadPrimarySource": [
"https://eplca.jrc.ec.europa.eu/permalink/EF3_1/EF-v3.1.zip"
]
}
}
],
"_sources": {
"prefLabel": "normalize_name_case",
"name": "bootstrap_labels",
"synonyms": "bootstrap_labels",
"context": "default_context_mapping",
"context_iri": "default_context_mapping",
"unit_iri": "unit_normalization",
"skos_definition": "enrich_references",
"references": "enrich_references",
"altLabel": "consensus_match",
"cas_match_labels": "consensus_match",
"concept_associations": "carry_associations_onto_flows",
"types": "link_flows_to_their_substance"
},
"cas_match_labels": {
"64742-78-5": "exactMatch"
},
"_transformed": true,
"_provided": {
"name": "residues (petroleum), hydrodesulfurized atmospheric tower",
"synonyms": [
"petroleum product",
"heavyfueloilacomplexcombinationofhydrocarbonsobtainedbytreatinganatmospherictowerresiduumwithhydrogeninthepresenceofacatalystunderconditionsprimarilytoremoveorganicsulfurcompounds.itconsistsofhydrocarbonshavingcarbonnumberspredominantlygreaterthanc20andboilingaboveapproximately350â°c(662â°f).thisstreamislikelytocontain5wt.%ormoreof4-to6-memberedcondensedringaromatichydrocarbons.",
"residues(petroleum),hydrodesulfurizedatmospherictower",
"residues(petroleum),hydrodesulfurizedatmospherictoweracomplexcombinationofhydrocarbonsobtainedbytreatinganatmospherictowerresiduumwithhydrogeninthepresenceofacatalystunderconditionsprimarilytoremoveorganicsulfurcompounds.itconsistsofhydrocarbonshavingcarbonnumberspredominantlygreaterthanc20andboilingaboveapproximately350â°c(662â°f).thisstreamislikelytocontain5wt.%ormoreof4-to6-memberedcondensedringaromatichydrocarbons.",
"[acomplexcombinationofhydrocarbonsobtainedbytreatinganatmospherictowerresiduumwithhydrogeninthepresenceofacatalystunderconditionsprimarilytoremoveorganicsulfurcompounds.itconsistsofhydrocarbonshavingcarbonnumberspredominantlygreaterthanc20andboilingaboveapproximately350â â°c(662â°f).thisstreamislikelytocontain5wt.â %ormoreof4-to6-memberedcondensedringaromatichydrocarbons.]acomplexcombinationofhydrocarbonsobtainedbytreatinganatmospherictowerresiduumwithhydrogeninthepresenceofacatalystunderconditionsprimarilytoremoveorganicsulfurcompounds.itconsistsofhydrocarbonshavingcarbonnumberspredominantlygreaterthanc20andboilingaboveapproximately350â°c(662â°f).thisstreamislikelytocontain5wt.%ormoreof4-to6-memberedcondensedringaromatichydrocarbons."
],
"context": [
"Emissions",
"Emissions to air",
"Emissions to urban air close to ground"
],
"cas_numbers": [
"64742-78-5"
],
"ec_numbers": [
"265-181-2"
],
"unit": "kg"
}
}