Brightway Flows 1.0
GitHub

Identity

Substance
fo-fa33fefe11011b4c Unclassified
Source
ecoinvent algorithm addition
Unit
MJ
Context
Environmental → Air → Medium stack, <150 meters → Rural (<1000 people/square mile)
CAS
—
EC
—

Context

Dimension
Environmental
Media
Air
Population density
Rural (<1000 people/square mile)
Strata
Medium stack, <150 meters

Source lists

2
List Version Source flow Name there Why this flow
ecoinvent 3.12 10f2525f-b35b-4d8a-ad99-03acf1afce6b Radiation, electromagnetic Nothing in the list carried this substance, so this flow was created from this row.
ecoinvent 3.8 10f2525f-b35b-4d8a-ad99-03acf1afce6b Radiation, electromagnetic This substance answers to the name the row carries; both name the same compartment.

Concept associations

2
Source list Source flow Name there Compartment there Match Conversion
ecoinvent 3.12 10f2525f-b35b-4d8a-ad99-03acf1afce6b Radiation, Electromagnetic air / non-urban air or from high stacks exactMatch —
ecoinvent 3.8 10f2525f-b35b-4d8a-ad99-03acf1afce6b Radiation, Electromagnetic air / non-urban air or from high stacks closeMatch —

History

The change log and the PROV-O trail (0 consensus changes)

Open the changes page

These are the heaviest sections of this page and the least often read, so the page does not pay for them until you ask.

Full record

Flow JSON
{
  "uuid": "5f73b8d695ce1bb2647356970a2bc0e99ad950f0",
  "identifier": "",
  "name": "Radiation, Electromagnetic",
  "source": "ecoinvent algorithm addition",
  "cas_numbers": [],
  "ec_numbers": [],
  "context": {
    "dimension": "Environmental",
    "media": "Air",
    "strata": "Medium stack, <150 meters",
    "population_density": "Rural (<1000 people/square mile)"
  },
  "synonyms": [],
  "lcia_methods": [],
  "unit": "MJ",
  "input_datasets": [],
  "prefLabel": [
    {
      "@value": "Radiation, Electromagnetic",
      "@language": "en",
      "@lang": "en",
      "provenance": {
        "prov:wasGeneratedBy": "bootstrap_labels",
        "prov:wasAttributedTo": "brightway-flows",
        "prov:hadPrimarySource": [
          "ecoinvent-3.12"
        ],
        "prov:wasDerivedFrom": "legacy name field"
      }
    }
  ],
  "altLabel": [],
  "context_iri": "https://vocab.brightway.one/flow-contexts/envi-air-mest15me-ru10pesq",
  "unit_iri": "https://vocab.brightway.one/units/unit/MegaJ",
  "flow_object_id": "fo-fa33fefe11011b4c",
  "properties": {},
  "references": [],
  "concept_associations": [
    {
      "@type": "xkos:ConceptAssociation",
      "xkos:sourceConcept": {
        "@id": "https://vocab.brightway.one/ecoinvent/3.12/flow/10f2525f-b35b-4d8a-ad99-03acf1afce6b",
        "skos:prefLabel": "Radiation, Electromagnetic",
        "context": "air / non-urban air or from high stacks",
        "qudt:hasUnit": {
          "@id": "https://vocab.brightway.one/units/unit/MegaJ"
        },
        "skos:exactMatch": {
          "@id": "https://vocab.brightway.dev/elementary-flows/5f73b8d695ce1bb2647356970a2bc0e99ad950f0"
        }
      },
      "xkos:targetConcept": {
        "@id": "https://vocab.brightway.dev/elementary-flows/5f73b8d695ce1bb2647356970a2bc0e99ad950f0"
      },
      "provenance": {
        "prov:wasGeneratedBy": "merge_ecoinvent",
        "prov:wasAttributedTo": "brightway-flows",
        "prov:hadPrimarySource": [
          "ecoinvent:3.12:10f2525f-b35b-4d8a-ad99-03acf1afce6b",
          "Radiation, Electromagnetic",
          ""
        ],
        "prov:wasDerivedFrom": "flow_object_creation:no-flow-object-candidate"
      }
    },
    {
      "@type": "xkos:ConceptAssociation",
      "xkos:sourceConcept": {
        "@id": "https://vocab.brightway.one/ecoinvent/3.8/flow/10f2525f-b35b-4d8a-ad99-03acf1afce6b",
        "skos:prefLabel": "Radiation, Electromagnetic",
        "context": "air / non-urban air or from high stacks",
        "qudt:hasUnit": {
          "@id": "https://vocab.brightway.one/units/unit/MegaJ"
        },
        "skos:closeMatch": {
          "@id": "https://vocab.brightway.dev/elementary-flows/5f73b8d695ce1bb2647356970a2bc0e99ad950f0"
        }
      },
      "xkos:targetConcept": {
        "@id": "https://vocab.brightway.dev/elementary-flows/5f73b8d695ce1bb2647356970a2bc0e99ad950f0"
      },
      "provenance": {
        "prov:wasGeneratedBy": "merge_ecoinvent",
        "prov:wasAttributedTo": "brightway-flows",
        "prov:hadPrimarySource": [
          "ecoinvent:3.8:10f2525f-b35b-4d8a-ad99-03acf1afce6b",
          "Radiation, Electromagnetic",
          "",
          "algorithm.lookup_order=cas>ec>label",
          "algorithm.basis=label:Radiation, Electromagnetic",
          "algorithm.flow_object_candidates=1",
          "algorithm.elementary_candidates=4",
          "algorithm.selector_reason=exact-context-iri-match",
          "algorithm.score_rule=exact-iri-shortcircuit;up-tree-filter;score=(2*unit_exact)+context_overlap-context_penalty+context_iri_exact;contradiction-veto"
        ],
        "prov:wasDerivedFrom": "algorithmic_fallback:lookup_order(cas>ec>label);basis(label:Radiation, Electromagnetic);flow_object_candidates(1);elementary_candidates(4);selector(exact-context-iri-match);exact-iri-shortcircuit;up-tree-filter;score=(2*unit_exact)+context_overlap-context_penalty+context_iri_exact;contradiction-veto"
      }
    }
  ],
  "_sources": {},
  "cas_match_labels": {},
  "general_comment": "",
  "_transformed": false,
  "_provided": {
    "name": null,
    "synonyms": [],
    "context": [],
    "cas_numbers": [],
    "ec_numbers": [],
    "unit": null
  },
  "elementary_flow_id": "5f73b8d695ce1bb2647356970a2bc0e99ad950f0"
}

Something wrong here?

A flow can be wrong in three ways, and they are decided differently. Pick the one that matches what you are looking at.

You do not need to run a build or clone anything. Name the row and say what your evidence is; the measurement is done for you. How contributing works

Keyboard

?
Show or hide this map
/
Focus search
Esc
Close